<em id="aepuz"><em id="aepuz"></em></em>
      <strong id="aepuz"><dl id="aepuz"></dl></strong>
        Welcome to Jiaozuo Libo Light Alloy Co., Ltd.

        Aluminum alloy sacrificial anode

        magnesium anode, zinc anode

        Telephone:

        0391-7588881 +8618739187123

        Jiaozuo Libo Light Alloy Co., Ltd.

        News

        News

        Contact

        Phone:18739187123

        hotline:0391-7588881

        E-mail:970512272@qq.com

        Address:Wuzhi County, Jiaozuo City, China

        Industry News

        Where does the current flow during cathodic protection?

        • Author:Libo
        • Source:wwww.gofitnessfreak.com
        • Date:2021-08-16
        • Click:0

        For long-distance pipeline, because the pipeline is not equal distance from each point is apart from the anode bed, all point to pipeline cathodic protection current by the resistance of the path is not equal, so the current density is not equal at every point, the anode and the distance protection structure analysis assumes that other factors constant, tank pipe protection structure point of anode current and its distance is inversely proportional to the distance. With the cathodic protection at the bottom of the tank, if the anode is too close to the bottom of the tank, the division of the current is very uneven, causing the side near the            anode to over-protect the other side of the protection is not enough. If the distance between the anode and the bottom of the tank increases, the resistance difference of the current loop between each point at the bottom of the tank and the anode decreases, and the current division tends to be uniform. As the distance between the anode and the bottom of the tank increases, the total resistance of the loop increases and the cathodic protection current decreases.

               The applied voltage needs to be raised, and the anode will have an optimal position from the perspective of current division. The distance between the anode and the tank bottom should not be less than the diameter of the tank. If there is a mistake, distributed anode or deep well anode should be used. The distance between the upper end of the deep well anode and the ground should not be less than 10m to make the current division uniform. For the long distance pipeline of cathodic protection, the uniform current distribution can be obtained by increasing the distance between the anode and the pipeline or by uniformly arranging the anode. Anode according to the pipeline is too close, will make close to the anode part of the pipeline protection, and far from the pipeline protection is not enough, the anode is too far from the pipeline, will make the whole pipeline under-protection, if the pipeline is fully protected, only to improve the applied voltage. Anode in the best position should make pipe far end get effective protection and aber not happened, because the current is also influenced by soil resistivity, anticorrosive coating condition, pipeline resistance, and many other factors, so the anode and pipe spacing should be not less than 100 m, soil resistivity influence on current distribution uniform when the soil resistivity, pipeline resistance ignoring the timing, The point nearest the anode has the highest current density.

        Online
        聯(lián)系方式

        熱線電話

        18739187123

        上班時間

        周一到周五

        公司電話

        0391-7588881

        国产V精品一区二区三区,亚洲另类国产欧美一区二区,国产精品嫩模大尺度视频,四虎国产精品永久地址49

          <em id="aepuz"><em id="aepuz"></em></em>
            <strong id="aepuz"><dl id="aepuz"></dl></strong>